interfaced with the
1818 to provide access control. Additionally, our elevator control module
restricts which floors a system user has access to making it an ideal
system for high rise buildings. This flexible system allows you to control
access by means of encoded cards, 5-digit PIN's (Personal Identification
Number), wireless RF control, or with most 26-bit weigand devices. Contact
your professional DKS system installer for more information about this
and other DKS products.
SPECIFICATIONS:
Provides access control for up to 3000 users. Memory sizes available: 25, 75, 125, 250, 500, 1000, 2000, 3000. Specify requirement when ordering.
Transaction buffer stores last 8000 events.
Stores up to 8000 access card codes - dependent on system memory.
31 security (permission) levels, 29 programmable with 4 time zones each.
8 hold open time zones.
Elevator control (note 1) for up to 4 elevators, each serving 64 floors.
Expandable (note 2) to control up to 16 entry points.
2 form "C" dry contact relays (2-door control standard. Expands to 16-door control).
EEPROM memory.
Requires touch-tone, loop-start central office phone line.
Two 16 VAC, 20 VA power transformers supplied.
FCC (US): DUF6VT-12874-OT-T
DOC (CAN): 1736 4528 A
Compliant with UL 294. ETL listed.
Dimensions:
Surface Mount: 10.25"H x 12.25"W x 4.25"D
Note 1: Requires Elevator Control Board.
Note 2: Requires Tracker Expansion Board(s).
OPTIONS AVAILABLE WITH THIS MODEL
Tracker expansion boards to control up to 16 entry points (one required per entry point). Tracker expansion boards record door ajar and forced entry data, and also provide gate operator data to the entry system.
Elevator control module. Each module controls one elevator shaft and 16 floors. You can add elevator control boards to control up to 4 elevator shafts with each elevator serving up to 64 floors.
RS-232 programming cable. |