Audio Signal
An audio signal is emitted when the minimum acceptable standard indicators
of high and low preset torque value is reached or the upper torque limit is
exceeded.
Visual Indicators
Bright green and red LED's are standard indicators of high and low preset
torque limits.
Over-Load Protection
The red LED flashes, the audio buzzer sounds and "OVER" is
displayed on the LCD when the torque range of the wrench is exceeded.
Earpiece Option
An external jack for remote earpiece signaling in noisy working
environments is available as an option.
|
New Liquid Crystal Display
Large sized Super Twist liquid crystal display incorporates technology
improving visibility of displayed data from any viewing angle. The display is
updated five times a second for changes in torque measurements. There is no
perceived lag between applying torque and updating the measurements on the LCD.
It is the fastest on the market.
Engineering Units
All seven basic engineering torque units are available on most Computorq 11
models (Ft. Lb., In. Lb., In. Oz., Nm, dNm, Mkg, or cmkg) and are easily
selected through the keypad.
Displayed Torque Measurements
Torque measurements captured on the display remain until they are erased,
sent to the wrench's memory, or down-loaded to an external device.
|