| BUTTONS |
| Reversing button: The first activation, makes the gate open, the
others, reverse the movement of the operator. While the gate is completely
open, the activation makes the door close. |
| Opening button: Used only to open the gate. |
| Closing button: Used only to close the gate. |
| Stop button: N.C. button. Stops opening/closing. |
| FOUR ADJUSTABLE TIMERS — (see timer table above) |
| White timer: Delay between electric lock activation and opening. |
| Red timer: Opening timer. Only controls opening time. |
| Yellow timer: Automatic closing timer. When the gate is opened, the timer is activated, and after this programmed time the door will automatically close. |
| Blue timer: Closing timer. Controls only the closing time. |
| *The panel contains a built-in timer of 2 seconds, to stop the operator when
a reverse operation occurs. |
| Open/Close Limit Switches: These switches stop the opening/closing. Remove two jumper wires if used. |
| Safety contact: To branch a photocell or sense output from a loop detector or reversing edge. The result is a reverse of movement during closing time. Not active when opening. |
| Electric lock output: 24 volt pulsed output (12 volt if
required). Two selectable times: short pulse (1 sec) or large pulse (8 sec.). |
| External light timer, contact output: This output provides a N.O.
pulse contact to start the activation of a light timer when opening. |
| Optional plug-in cards: RTC (remote & decoder control card) or DTC
(decoder control card). These cards allow you to connect digital keyboards
and magnetic key readers to the panel. RTC is also a receiver card. |
| Flashing light card: Provides a flashing contact before and during
opening/closing. |
| Traffic light card: Controls a red/green traffic light. |
| Alarm output card: Provides an alarm contact (N.C. and N.O.) when the gate is manually opened during standby position or when a second car tries to pass after an allowed user (if option 7 is selected).
|
| Thermal contact: Many motors provide an N.C. contact output when
motor temperature increases to a predetermined setting. This activation stops all functions when the motor hits that high-temperature setting.
|
Power output: You can connect motors until you reach a total valve of 1/2 hp. |