Specifications |
| Power
Source |
18V DC. Use PS-18C for initial three video
monitors. Use PS-18YC/A for each additional two
monitors. |
| Communication |
Through Panasonic
phone system. |
| Current
Consumption |
MY-CU-PH: Standby:
0.12A; Max. 0.9A. MYH-CU: Standby: 0.0A; Max. 0.4A. |
| Calling: |
Monitors turn on
and telephones ring. |
| Scanning
Lines: |
525
Lines. |
| Wiring |
2 conductor,
18AWG, non-shielded (Use Aiphone #841802.) 6 wires, looped to
Monitors. (Use Aiphone #841806.) 4 wires to phone system (audio).
|
| Wiring
Distance: |
MY Camera to
MY-CU-PH: 330’ with 18AWG wire. MY-CU-PH to last MYH-CU: 245’
with 18AWG wire. PS-18C to MY-CU-PH: 16’ with 18AWG wire. (Use
Aiphone #841802.) |
| Mounting: |
Surface mounts to
2-gang box. |